Tuesday, June 27, 2023

DPS Differential Pressure Switches

A differential pressure switch is a device used to monitor and control the difference in pressure between two points in a system. It is commonly used in industrial applications to ensure proper functioning and safety of various processes.

The working principle of a differential pressure switch involves a mechanical or electronic mechanism that responds to changes in pressure and triggers a switch or relay to open or close an electrical circuit. Here's a general overview of how a mechanical differential pressure switch typically operates:

  1. Pressure Sensing: The differential pressure switch consists of two pressure ports, typically labeled as "High" and "Low." These ports are connected to the system or process being monitored. The difference in pressure between these two ports is what the switch measures.

  2. Mechanical Sensing Mechanism: Inside the differential pressure switch, there is a diaphragm or a piston mechanism that responds to changes in pressure. When the pressure difference between the two ports reaches a certain threshold, it causes the diaphragm or piston to move.

  3. Contact Switch: The movement of the diaphragm or piston actuates a set of contacts, typically a snap-action switch, inside the differential pressure switch. This action either opens or closes the electrical circuit connected to the switch.

  4. Electrical Control: The electrical circuit connected to the differential pressure switch can be used for various purposes, such as activating alarms, indicating pressure conditions, or controlling other equipment. For example, the switch can trigger an alarm when the pressure difference exceeds a predetermined limit or start/stop a pump based on the pressure conditions.

By using a differential pressure switch, operators can monitor the pressure difference in a system and take appropriate actions based on the switch's response. This helps ensure the system operates within safe parameters, prevents damage or malfunctions, and allows for timely maintenance or intervention if needed.

Saturday, June 10, 2023

How to automatically water in chiller

To put water in a chiller water-cooled condenser, you will typically follow these steps:

Identify the water supply: Locate the water supply source for the chiller system. It could be a dedicated water line or a cooling tower.

Check the water quality: Ensure that the water supply meets the required specifications and is suitable for use in the chiller system. It should be clean, free from impurities, and within the recommended temperature range.

Locate the condenser water inlet and outlet: The chiller unit will have designated inlet and outlet connections for the condenser water. These are usually labeled or indicated in the equipment manual.

Connect the water supply: Use appropriate plumbing connections to connect the water supply to the chiller condenser water inlet. Ensure that the connections are secure and leak-free.

Open the water supply valve: Turn on the water supply valve gradually to allow water to flow into the chiller condenser. Start with a slow flow rate initially.

Monitor the water flow: Observe the water flow into the chiller condenser. Ensure that it is steady and consistent. Adjust the flow rate if necessary.

Bleed the air: Depending on the chiller system, there may be air trapped in the condenser or water lines. It is important to bleed the air out of the system to ensure proper cooling efficiency. Follow the manufacturer's instructions for bleeding air from the specific chiller model.

Check for leaks: While the water is flowing, inspect all connections and joints for any signs of leaks. If you notice any leaks, address them promptly to prevent water wastage or damage to the chiller system.

Monitor system performance: Once the water is flowing smoothly, monitor the chiller system's performance to ensure it is operating within the desired temperature and pressure ranges.

Please note that these instructions provide a general guideline, and the specific steps may vary depending on the type and model of the chiller system you are working with. Always refer to the manufacturer's instructions and guidelines for your particular equipment to ensure proper and safe operation.

Thursday, June 8, 2023

how to Jumper for run FCU

How to jumper for run FCU

To jumper for running a Fan Coil Unit (FCU), you can follow these general steps:

Ensure Safety: Before performing any electrical work, make sure to turn off the power supply to the FCU at the circuit breaker or disconnect switch. This step is crucial to prevent electrical shocks or accidents.

Identify the Control Wiring: Locate the control terminal strip or control board of the FCU. This is where the control wires from the thermostat or building automation system are connected.

Locate the Run Terminal: On the control terminal strip or control board, identify the terminal labeled "Run" or "R" for the fan motor. This terminal is typically used to supply power to the fan motor when the FCU is operational.

Identify the Common Terminal: Locate the terminal labeled "Common" or "C" on the control terminal strip or control board. This terminal is the common connection point for the control circuit.

Connect the Jumper Wire: Take a jumper wire or a short piece of wire and connect one end to the "Run" terminal and the other end to the "Common" terminal. This creates a direct connection between the power source and the fan motor, bypassing any control signals from the thermostat or building automation system.

Secure the Jumper Wire: Ensure that the jumper wire is securely connected to both terminals. You may use appropriate connectors or tighten terminal screws, depending on the type of connection used on the control terminal strip or control board.

Inspect and Test: After connecting the jumper wire, visually inspect the connections to ensure they are secure and free from any exposed wires. Once everything is in order, restore power to the FCU at the circuit breaker or disconnect switch. Test the FCU to verify that the fan motor is running by turning on the system or manually triggering the fan operation.

Remember, this general guide assumes basic knowledge of electrical systems and control wiring. If you are unsure or uncomfortable with electrical work, it is always recommended to consult a qualified HVAC technician or electrician to perform the task safely and correctly.

HVAC Component Right

Here is a list of common HVAC (Heating, Ventilation, and Air Conditioning) equipment:

Furnace: A heating device that burns fuel (such as natural gas, oil, or propane) or uses electricity to generate heat for the building.

Air Conditioner: A cooling system that removes heat from the indoor air and circulates cooled air throughout the building. It typically consists of an outdoor condenser unit and an indoor evaporator unit.

Heat Pump: A device that can both heat and cool a building by transferring heat between the indoor and outdoor environments. It operates similarly to an air conditioner but can also reverse its cycle to provide heating during colder seasons.

Boiler: A heating system that uses water or steam to distribute heat throughout the building. Boilers can be fueled by gas, oil, or electricity.

Air Handler: A unit that circulates and filters air in the HVAC system. It contains a blower, heating and cooling elements, and a filter.

Thermostat: A control device that allows users to set and adjust the temperature in a building. It communicates with the HVAC system to maintain the desired temperature.

Ventilation Fans: Fans or blowers used to bring fresh outdoor air into the building and exhaust stale air. They help improve indoor air quality and remove odors, moisture, and contaminants.

Ductwork: A system of channels or pipes that distribute heated or cooled air throughout the building. It includes supply ducts that deliver conditioned air and return ducts that bring back the air for reconditioning.

Humidifier: A device that adds moisture to the air to prevent dryness, particularly during the winter when the heating system can dry out the indoor air.

Air Purifier: A system that removes pollutants, allergens, and contaminants from the air, enhancing indoor air quality.

VAV Boxes: Variable Air Volume (VAV) boxes control the airflow in different zones of a building. They regulate the amount of air entering a space to maintain the desired temperature.

Exhaust Fans: Fans used to remove stale air, smoke, and odors from specific areas like kitchens, bathrooms, or industrial spaces.

Dampers: Devices that regulate or control airflow in ducts by opening or closing to redirect air or adjust the pressure in specific areas.

Condensing Unit: The outdoor component of an air conditioning or heat pump system that releases heat from the refrigerant.

Evaporator Coil: The indoor component of an air conditioning or heat pump system that absorbs heat from the indoor air and cools it.

Please note that this is not an exhaustive list, and there are various other specialized HVAC equipment and components used in different applications and systems.

Transducer working way

A transducer converts one form of energy into another. In the context of sensors, it typically transforms a physical quantity (like pressure...